• ARTG54LDTA
  • ARTG54LDTA

FUJITSU INVERTER – DUCTED – SINGLE PHASE 15.8KW(C)/ 18.0KW(H) – ARTG60LDTA

SKU: 9328420045649
$5,330.00
In Stock

Only 2 left in stock (can be backordered)

SKU: 9328420045649 Categories: , ,
  • Delivery Icon

    Fast Dispatch & delivery

  • Flag

    Australian owned

  • Map

    Shipping Australia Wide

  • Time

    Fast response time

  • Charge

    Low Delivery charges

Ftpay
  • Product Description
  • Additional Information

Product Description

Separation of the evaporator is possible by lightweight and compact design. The indoor unit can be separated into the fan drive unit and the heat-exchanger unit to fit through the intake grill space or the roof access door.

FEATURES

AUTOMATIC AIR FLOW ADJUSTMENT
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.

PROGRAM TIMER
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.

FILTER SIGN
Indicates the filter cleaning period by lamp.

ON-OFF TIMER
ON-OFF timer can be set to operate once every 24 hours.

BLUE FIN HEAT EXCHANGER
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchange.

CONNECTABLE DISTRIBUTING DUCT
Conditioned air can be distributed to adjacent areas by means of a distribution duct.

CONNECTABLE FRESH AIR DUCT
Allows introduction of fresh air to occupied space.

AUTO RESTART
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.

ECONOMY MODE
Limits the maximum operation current, and performs operation with the power consumption suppressed.

CONTROL PORT
External inputs and outputs contained within the product allow on/off control, fresh air interlock connection and heater bank element connection. UTD-ECS5A* (optional parts). * Selected ducted units only.

ALL DC
With All DC, electricity loss is decreased and power consumption reduced.

AUTO-CHANGEOVER
The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.

FRESH AIR INTAKE
Fresh air can be taken in by a fan which can be connected using UTD-ECS5A* (optional parts). *Selected ducted units only

WEEKLY TIMER
Different on-off times can be set for up to 7 days.

SPECIFICATIONS

Model No. – Indoor
ARTG60LDTA

Model No. – Outdoor
AOTG60LBTA

Reverse Cycle System
Yes

Capacity Class

Cooling Capacity (Watts)
15,800

Cooling Capacity (BTU/h)
53,900

Range (Watts)
6,200—16,300

Range (BTU/h)
21,200—55,600

Heating Capacity (Watts)
18,000

Heating Capacity (BTU/h)
61,500

Range (Watts)
6,200—18,500

Range (BTU/h)
21,200—63,100

Power Supply (Volts)
240

Phase-Frequency (Ph – Hz)
50

Power Supply Attachment
Outdoor Unit

Plug Size (If Applicable)
N/A

Running Current, Cooling (Amps)
20.7

Running Current, Range (Amps)
26.0 (Maximum)

Input, Cooling (Watts)
4,920

Input, Range (Watts)
6,150 (Max)

Running Current, Heating (Amps)
21.0

Running Current, Range (Amps)
26.0 (Maximum)

Input, Heating (Watts)
4,990

Input, Range (Watts)
6.18 (Max)

Input (Watts)

Moisture Removal (l/hr)
2.1

E.E.R. – Cooling
3.21

C.O.P. – Heating
3.61

Star Rating – Cooling

Star Rating – Heating

Fan Speed
4

Air Circulation, High (l/s)
1,139

Compressor Type
Twin rotary × 1

Dimensions – Inside Unit (HxWxD mm)
360 × 1,400 × 850

Weight – Inside Unit (kg)
69

Dimensions – Outside Unit (HxWxD mm)
1,290 × 900 × 330

Weight – Outside Unit (kg)
93

I.U. Sound Pressure Level (dBA@1mtr)
44

O.U. Sound Pressure Level (dBA@1mtr)
59

O.U. Sound Power Level (dBA)
72

Refrigerant Type
R410A

Connection Pipe Sizes, Gas (mm)
15.88

Connection Pipe Sizes, Liquid (mm)
9.52

Pre Charged Length (Metre)
30

Minimum Pipe Length (Metre)
5

Maximum Pipe Length (Metre)
75

Maximum Pipe Height (Metre)
30

Pipe Connection Methods
Flared

Outdoor operating Temp, Cooling Degrees C
-15 to 46

Outdoor operating Temp, Heating Degrees C
-15 to 24